Thermal Conductivity Converter

Convert thermal conductivity between clearly labelled units with an instant result and the conversion method shown.

START HERE

Bring your number.

YOUR RESULT LOCAL & INSTANT
Ready when you are.

Calculations stay in this browser. Your input is not uploaded.

Keep thickness separate from the property

For an insulation comparison, convert conductivities under similar conditions. Calculate the component’s thermal performance separately using its thickness and complete boundary model.

The following inputs stay in watts/(metre kelvin) and the results use btu (it)/(hour foot °f). They illustrate different magnitudes for this measurement. Retain the specific conditions described above when replacing an example with your own value.

0.02 W/(m·K)0.0115557863309 BTU/(h·ft·°F)
0.04 W/(m·K)0.0231115726617 BTU/(h·ft·°F)
0.08 W/(m·K)0.0462231453234 BTU/(h·ft·°F)

This thermal conductivity unit pair has a constant factor ratio. Changing the input changes the output by the same proportion. If a copied figure differs by an unexpected factor, review the full unit symbol before changing the source measurement. Use the relevant directional material data for anisotropic materials.

Align the material conditions and conductivity unit, then model the specified thickness and complete assembly separately.

Conductivity does not determine an insulation assembly by itself

An insulation data sheet reports conductivity while a building calculation asks for thermal resistance or a U-value. Converting conductivity to another unit can be useful, but it cannot supply the thickness, boundary resistances or construction details that connect those different quantities.

For an illustrative uniform layer with conductivity 0.04 W/(m·K) and thickness 0.1 m, the simple conductive resistance per area is thickness divided by conductivity, or 2.5 m²·K/W. That relationship assumes an appropriate steady one-dimensional model and omits surface and other assembly effects.

Changing conductivity units does not change layer thickness. A thin high-resistance material and a thick layer can therefore give different assembly behaviour even when their conductivity labels seem comparable. Moisture, temperature and direction can also affect the material property reported by a source.

Keep conductivity, thickness and the resulting resistance as distinct quantities. Thermal resistance per area and whole-object resistance have different units, and a product R-value can use a different convention. For a building or equipment assessment, use the specified assembly method and conditions. The converter supplies an equivalent conductivity, leaving bridges, contact layers and boundary effects outside its scope.

An illustrative thermal conductivity conversion
Original measurement0.04 W/(m·K)
The same quantity0.0231115726617 BTU/(h·ft·°F)

0.1 m ÷ 0.04 W/(m·K) = 2.5 m²·K/W in the stated layer model.

What this thermal conductivity comparison can tell you

Useful capabilities

Align the material conditions and conductivity unit, then model the specified thickness and complete assembly separately.

The listed units express the same supplied thermal conductivity quantity. The 0.04 W/(m·K) → 0.0231115726617 BTU/(h·ft·°F) example makes the selected convention visible before it is used in a longer calculation.

Important limits

Conductivity differs from conductance and heat transfer coefficient. Temperature and material direction can matter.

Thickness, geometry and boundary resistances must be considered. Use the relevant directional material data for anisotropic materials.

Using conductivity directly as a wall U-value

Thickness, geometry and boundary resistances must be considered.

Assuming a constant value applies in every direction

Use the relevant directional material data for anisotropic materials.

Conductivity may depend on temperature, moisture and material direction. An ideal layer resistance needs thickness as another input and uses a different unit. Surface films, thermal bridges and contact layers can affect an assembly beyond the simple layer calculation. Preserve the test conditions instead of presenting a converted conductivity as the completed insulation performance of a building or device.

As a controlled uncertainty example, suppose the original 0.04 W/(m·K) record had a stated ±1% input interval. Its endpoints would be 0.0396 W/(m·K) and 0.0404 W/(m·K). Converting those endpoints gives an output interval from 0.0228804569351 BTU/(h·ft·°F) to 0.0233426883883 BTU/(h·ft·°F). The interval scales with the same fixed unit ratio as the central value. This chosen interval illustrates the arithmetic and is not an accuracy claim for your measurement.

0.04 W/(m·K) in btu (it)/(hour foot °f)

Watts/(metre kelvin) → BTU (IT)/(hour foot °F)

0.04 W/(m·K) 0.0231115726617 BTU/(h·ft·°F)

Output = input × source factor ÷ destination factor

0.04 × 1 ÷ 1.73073466637 = 0.0231115726617 BTU/(h·ft·°F). The two factors express the source and destination relative to the same internal reference unit. Their ratio is the multiplier.

Both unit factors refer to the same internal reference for thermal conductivity. Multiplying by the source factor and dividing by the destination factor changes the numerical scale while retaining the quantity. The source definition still matters: Thickness, geometry and boundary resistances must be considered.

Reversing the unrounded 0.0231115726617 BTU/(h·ft·°F) result returns 0.04 W/(m·K). Use this as a direction check. A consistent reverse calculation cannot resolve using conductivity directly as a wall u-value or improve the original observation.

Material conductivity and layer resistance

Thermal conductivity describes a material’s response to a temperature gradient. Convert W/(m·K), W/(cm·K), mW/(m·K) or BTU (IT)/(h·ft·°F) for a supplied value. It is a material property rather than a complete heat-loss rating for a component or wall.

For a simple one-dimensional steady model, heat rate is kAΔT/L. The converter changes k’s units; it does not provide area, thickness or boundary conditions. Materials can be anisotropic, and conductivity can vary with temperature or moisture. Thermal conductance and an overall heat transfer coefficient require geometry and additional resistances.

A simple one-dimensional conduction model gives heat rate kAΔT/L. Conductivity k describes the material under stated conditions, while geometry supplies area and thickness. Moisture, temperature and material direction can affect k. Contact and surface effects may also matter in a complete assembly. Matching units does not make a material value equal to an assembly performance rating.

The distinction that matters

Align the material conditions and conductivity unit, then model the specified thickness and complete assembly separately.

Thermal Conductivity units, side by side

The values below all describe 0.04 W/(m·K). They provide a comparison of unit sizes for thermal conductivity; they are not separate measurements. Read the complete symbol and convention before copying a number.

Alternative units for 0.04 W/(m·K)
UnitSymbolEquivalent
Watts/(metre kelvin)W/(m·K)0.04 W/(m·K)
Watts/(centimetre kelvin)W/(cm·K)0.0004 W/(cm·K)
Milliwatts/(metre kelvin)mW/(m·K)40 mW/(m·K)
BTU (IT)/(hour foot °F)BTU/(h·ft·°F)0.0231115726617 BTU/(h·ft·°F)

Keep the original watts/(metre kelvin) record alongside the converted btu (it)/(hour foot °f) display. The unit list uses up to twelve significant digits for arithmetic readability, while the measurement precision still comes from its source.

Before using this thermal conductivity result

  • Keep material composition, direction and temperature with the value.
  • Distinguish conductivity k from conductance and an overall U-value.
  • Check that the source’s temperature unit describes an interval.

Keep the original thermal conductivity value, its unit and the relevant conditions in the record. A copied answer of 0.0231115726617 BTU/(h·ft·°F) is interpretable only when those details remain available. State which of the measurement checks above you verified before using the value in another calculation.

Questions about thermal conductivity

Why does W/(cm·K) have a larger unit factor?

A centimetre is a smaller length denominator. One W/(cm·K) equals 100 W/(m·K); changing a denominator reverses the intuitive prefix direction.

Does this predict heat loss through insulation?

The unit conversion alone cannot. A model also needs thickness, area, temperature difference and relevant boundary or contact effects.